 "schema_version": 0,
 "id": "bb:product:viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp",
 "url": "https://bedandbot.it/p/viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp/",
 "json": "https://bedandbot.it/p/viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp.json",
 "manufacturer": "Viessmann",
 "model_family": "Vitocal 250-A",
 "model_code": "Vitocal 150-A AWO-M-E-AC 151.A10 SP",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "1x230V 50Hz",
 "outdoor_unit": "Vitocal 151.A10",
 "values": [
  {
   "id": "bb:value:25720",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 190.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "η s 190 % 145 %",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25710",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 160.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "η s 160 % 127 %",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25700",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 239.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "η s 239 % 168 %",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25721",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 145.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "η s 190 % 145 %",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25711",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 127.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "η s 160 % 127 %",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25701",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 168.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "η s 239 % 168 %",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25722",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 9.8,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Prated 9.80 kW 9.37 kW",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25712",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.48,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Prated 8.48 kW 7.98 kW",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25702",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.27,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Prated 5.27 kW 4.65 kW",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25723",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 9.37,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Prated 9.80 kW 9.37 kW",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25713",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.98,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Prated 8.48 kW 7.98 kW",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25703",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 4.65,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Prated 5.27 kW 4.65 kW",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25730",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 2.0,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Mass of Refrigerant 2,000 kg",
    "location": "subtype Vitocal x50-A z4, general data"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25724",
   "property": "scop",
   "label": "SCOP",
   "value": 4.83,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "SCOP 4.83 3.70",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25714",
   "property": "scop",
   "label": "SCOP",
   "value": 4.08,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "SCOP 4.08 3.25",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25704",
   "property": "scop",
   "label": "SCOP",
   "value": 6.04,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "SCOP 6.04 4.27",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25725",
   "property": "scop",
   "label": "SCOP",
   "value": 3.7,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "SCOP 4.83 3.70",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25715",
   "property": "scop",
   "label": "SCOP",
   "value": 3.25,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "SCOP 4.08 3.25",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25705",
   "property": "scop",
   "label": "SCOP",
   "value": 4.27,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "SCOP 6.04 4.27",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25726",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25716",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25706",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25727",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25717",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25707",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25728",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25718",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -20.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "TOL -20 °C -20 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25708",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25729",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25719",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -20.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "TOL -20 °C -20 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:25709",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6377&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=82bb0bc94f414b369fa11f7fddaa9cbe",
    "reference": "011-1W0465",
    "document_date": "2021-12-15",
    "retrieved": "2026-10-03T19:45:36+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model Vitocal 150-A AWO-M-E-AC 151.A10 SP, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp:cop-a7w35",
   "question": "We have no manufacturer-stated heating capacity and COP at A7/W35 (EN 14511) for this unit. If you know an official datasheet or manual from the manufacturer that states them, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp:cop-a7w35",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  },
  {
   "id": "q:viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:viessmann-vitocal-150-a-awo-m-e-ac-151-a10-sp:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  }
 ]
}