Viessmann Vitocal 250-A PRO AWO-AC-AF251.A40

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Vitocal 250-A

Machine-readable: https://bedandbot.it/p/viessmann-vitocal-250-a-pro-awo-ac-af251-a40.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application191 %HP Keymark 011-1W0833
“η s 191 % 151 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application161 %HP Keymark 011-1W0833
“η s 161 % 132 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application267 %HP Keymark 011-1W0833
“η s 267 % 197 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application151 %HP Keymark 011-1W0833
“η s 191 % 151 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application132 %HP Keymark 011-1W0833
“η s 161 % 132 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application197 %HP Keymark 011-1W0833
“η s 267 % 197 %”
Rated heat output (Prated)average climate, 35 °C application24.8 kWHP Keymark 011-1W0833
“Prated 24.80 kW 25.60 kW”
Rated heat output (Prated)colder climate, 35 °C application26.8 kWHP Keymark 011-1W0833
“Prated 26.80 kW 27.40 kW”
Rated heat output (Prated)warmer climate, 35 °C application27.4 kWHP Keymark 011-1W0833
“Prated 27.40 kW 28.10 kW”
Rated heat output (Prated)average climate, 55 °C application25.6 kWHP Keymark 011-1W0833
“Prated 24.80 kW 25.60 kW”
Rated heat output (Prated)colder climate, 55 °C application27.4 kWHP Keymark 011-1W0833
“Prated 26.80 kW 27.40 kW”
Rated heat output (Prated)warmer climate, 55 °C application28.1 kWHP Keymark 011-1W0833
“Prated 27.40 kW 28.10 kW”
Refrigerant charge—3.3 kgHP Keymark 011-1W0833
“Mass of Refrigerant 3,300 kg”
SCOPaverage climate, 35 °C application4.85 HP Keymark 011-1W0833
“SCOP 4.85 3.85”
SCOPcolder climate, 35 °C application4.1 HP Keymark 011-1W0833
“SCOP 4.10 3.37”
SCOPwarmer climate, 35 °C application6.74 HP Keymark 011-1W0833
“SCOP 6.74 5.01”
SCOPaverage climate, 55 °C application3.85 HP Keymark 011-1W0833
“SCOP 4.85 3.85”
SCOPcolder climate, 55 °C application3.37 HP Keymark 011-1W0833
“SCOP 4.10 3.37”
SCOPwarmer climate, 55 °C application5.01 HP Keymark 011-1W0833
“SCOP 6.74 5.01”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0833
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0833
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0833
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0833
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0833
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0833
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0833
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0833
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0833
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0833
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0833
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0833
“TOL 2 °C 2 °C”

Open questions