 "schema_version": 0,
 "id": "bb:product:viessmann-vitocal-250-ah-hawo-ac-af-252-a19",
 "url": "https://bedandbot.it/p/viessmann-vitocal-250-ah-hawo-ac-af-252-a19/",
 "json": "https://bedandbot.it/p/viessmann-vitocal-250-ah-hawo-ac-af-252-a19.json",
 "manufacturer": "Viessmann",
 "model_family": "Vitocal 250-A",
 "model_code": "Vitocal 250-AH HAWO-AC-AF 252.A19",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "3x400V 50Hz",
 "values": [
  {
   "id": "bb:value:7103",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 191.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "η s 191 % 152 %",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7093",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 147.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "η s 147 % 121 %",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7083",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 215.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "η s 215 % 159 %",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7104",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 152.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "η s 191 % 152 %",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7094",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 121.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "η s 147 % 121 %",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7084",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 159.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "η s 215 % 159 %",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7105",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 13.61,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Prated 13.61 kW 13.18 kW",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7095",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 18.67,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Prated 18.67 kW 18.53 kW",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7085",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.22,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Prated 7.22 kW 6.73 kW",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7106",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 13.18,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Prated 13.61 kW 13.18 kW",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7096",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 18.53,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Prated 18.67 kW 18.53 kW",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7086",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 6.73,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Prated 7.22 kW 6.73 kW",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7113",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 2.0,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Mass of Refrigerant 2,000 kg",
    "location": "subtype Vitocal 250-A z5, general data"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7107",
   "property": "scop",
   "label": "SCOP",
   "value": 4.86,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "SCOP 4.86 3.89",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7097",
   "property": "scop",
   "label": "SCOP",
   "value": 3.75,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "SCOP 3.75 3.10",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7087",
   "property": "scop",
   "label": "SCOP",
   "value": 5.44,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "SCOP 5.44 4.05",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7108",
   "property": "scop",
   "label": "SCOP",
   "value": 3.89,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "SCOP 4.86 3.89",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7098",
   "property": "scop",
   "label": "SCOP",
   "value": 3.1,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "SCOP 3.75 3.10",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7088",
   "property": "scop",
   "label": "SCOP",
   "value": 4.05,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "SCOP 5.44 4.05",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7109",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Tbiv -7 °C -8 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7099",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -8.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Tbiv -8 °C -8 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7089",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7110",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -8.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Tbiv -7 °C -8 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7100",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -8.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Tbiv -8 °C -8 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7090",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7111",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7101",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -20.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "TOL -20 °C -20 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7091",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7112",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7102",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -20.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "TOL -20 °C -20 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:7092",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6681&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c796eed8df8c0075782226a33aeebee5",
    "reference": "011-1W0776",
    "document_date": "2024-03-11",
    "retrieved": "2026-10-03T19:43:43+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model Vitocal 250-AH HAWO-AC-AF 252.A19, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:viessmann-vitocal-250-ah-hawo-ac-af-252-a19:cop-a7w35",
   "question": "We have no manufacturer-stated heating capacity and COP at A7/W35 (EN 14511) for this unit. If you know an official datasheet or manual from the manufacturer that states them, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:viessmann-vitocal-250-ah-hawo-ac-af-252-a19:cop-a7w35",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  },
  {
   "id": "q:viessmann-vitocal-250-ah-hawo-ac-af-252-a19:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:viessmann-vitocal-250-ah-hawo-ac-af-252-a19:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  }
 ]
}