 "schema_version": 0,
 "id": "bb:product:wolf-cha-10-400v",
 "url": "https://bedandbot.it/p/wolf-cha-10-400v/",
 "json": "https://bedandbot.it/p/wolf-cha-10-400v.json",
 "manufacturer": "Wolf",
 "model_family": "CHA-Monoblock",
 "model_code": "CHA-10/400V",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "3x400V 50Hz",
 "values": [
  {
   "id": "bb:value:16352",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 191.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "η s 191 % 141 %",
    "location": "model CHA-10/400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16342",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 177.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "η s 177 % 135 %",
    "location": "model CHA-10/400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16332",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 272.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "η s 272 % 185 %",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16353",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 141.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "η s 191 % 141 %",
    "location": "model CHA-10/400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16343",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 135.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "η s 177 % 135 %",
    "location": "model CHA-10/400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16333",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 185.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "η s 272 % 185 %",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16354",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.58,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Prated 7.58 kW 7.40 kW",
    "location": "model CHA-10/400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16344",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.78,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Prated 8.78 kW 8.17 kW",
    "location": "model CHA-10/400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16334",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.57,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Prated 8.57 kW 8.64 kW",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16355",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.4,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Prated 7.58 kW 7.40 kW",
    "location": "model CHA-10/400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16345",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.17,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Prated 8.78 kW 8.17 kW",
    "location": "model CHA-10/400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16335",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.64,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Prated 8.57 kW 8.64 kW",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16362",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 3.4,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Mass of Refrigerant 3,400 kg",
    "location": "subtype CHA-10/400V, general data"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16356",
   "property": "scop",
   "label": "SCOP",
   "value": 4.86,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "SCOP 4.86 3.60",
    "location": "model CHA-10/400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16346",
   "property": "scop",
   "label": "SCOP",
   "value": 4.5,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "SCOP 4.50 3.44",
    "location": "model CHA-10/400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16336",
   "property": "scop",
   "label": "SCOP",
   "value": 6.88,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "SCOP 6.88 4.71",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16357",
   "property": "scop",
   "label": "SCOP",
   "value": 3.6,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "SCOP 4.86 3.60",
    "location": "model CHA-10/400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16347",
   "property": "scop",
   "label": "SCOP",
   "value": 3.44,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "SCOP 4.50 3.44",
    "location": "model CHA-10/400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16337",
   "property": "scop",
   "label": "SCOP",
   "value": 4.71,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "SCOP 6.88 4.71",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16358",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model CHA-10/400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16348",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -17.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Tbiv -17 °C -17 °C",
    "location": "model CHA-10/400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16338",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16359",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model CHA-10/400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16349",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -17.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Tbiv -17 °C -17 °C",
    "location": "model CHA-10/400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16339",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16360",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model CHA-10/400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16350",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model CHA-10/400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16340",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16361",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model CHA-10/400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16351",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model CHA-10/400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  },
  {
   "id": "bb:value:16341",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=7567&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=38491bb2ee761a7a604ea4b453e2adda",
    "reference": "011-1W0381",
    "document_date": "2023-01-27",
    "retrieved": "2026-10-04T03:17:08+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model CHA-10/400V, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T03:17:08+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:wolf-cha-10-400v:cop-a7w35",
   "question": "We have no manufacturer-stated heating capacity and COP at A7/W35 (EN 14511) for this unit. If you know an official datasheet or manual from the manufacturer that states them, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:wolf-cha-10-400v:cop-a7w35",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  },
  {
   "id": "q:wolf-cha-10-400v:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:wolf-cha-10-400v:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  }
 ]
}