Buderus Logatherm WLW186i-4 AR TP70 W

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw186i-4-ar-tp70-w.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application179 %HP Keymark 011-1W0582
“η s 179 % 128 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application154 %HP Keymark 011-1W0582
“η s 154 % 105 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application209 %HP Keymark 011-1W0582
“η s 209 % 142 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application128 %HP Keymark 011-1W0582
“η s 179 % 128 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application105 %HP Keymark 011-1W0582
“η s 154 % 105 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application142 %HP Keymark 011-1W0582
“η s 209 % 142 %”
Rated heat output (Prated)average climate, 35 °C application4.4 kWHP Keymark 011-1W0582
“Prated 4.4 kW 4 kW”
Rated heat output (Prated)colder climate, 35 °C application3.8 kWHP Keymark 011-1W0582
“Prated 3.8 kW 3.2 kW”
Rated heat output (Prated)warmer climate, 35 °C application4.3 kWHP Keymark 011-1W0582
“Prated 4.3 kW 3.8 kW”
Rated heat output (Prated)average climate, 55 °C application4 kWHP Keymark 011-1W0582
“Prated 4.4 kW 4 kW”
Rated heat output (Prated)colder climate, 55 °C application3.2 kWHP Keymark 011-1W0582
“Prated 3.8 kW 3.2 kW”
Rated heat output (Prated)warmer climate, 55 °C application3.8 kWHP Keymark 011-1W0582
“Prated 4.3 kW 3.8 kW”
Refrigerant charge—0.95 kgHP Keymark 011-1W0582
“Mass of Refrigerant 0,950 kg”
SCOPaverage climate, 35 °C application4.55 HP Keymark 011-1W0582
“SCOP 4.55 3.27”
SCOPcolder climate, 35 °C application3.93 HP Keymark 011-1W0582
“SCOP 3.93 2.71”
SCOPwarmer climate, 35 °C application5.3 HP Keymark 011-1W0582
“SCOP 5.30 3.62”
SCOPaverage climate, 55 °C application3.27 HP Keymark 011-1W0582
“SCOP 4.55 3.27”
SCOPcolder climate, 55 °C application2.71 HP Keymark 011-1W0582
“SCOP 3.93 2.71”
SCOPwarmer climate, 55 °C application3.62 HP Keymark 011-1W0582
“SCOP 5.30 3.62”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”