NIBE S2125-12 3x400V

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family S2125

Machine-readable: https://bedandbot.it/p/nibe-s2125-12-3x400v.json

PropertyConditionsValueSource
Cooling capacityA35/W18, non_dichiarato load8.68 kWNIBE
“Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93”
Cooling capacityA35/W7, non_dichiarato load6.69 kWNIBE
“Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08”
COPA-7/W35, partial load2.65 NIBE
“Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64”
COPA2/W35, partial load4.32 NIBE
“Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63”
COPA7/W35, partial load5.24 NIBE
“7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55”
COPA7/W45, partial load3.94 NIBE
“7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12”
EERA35/W18, non_dichiarato load3.34 NIBE
“Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93”
EERA35/W7, non_dichiarato load2.77 NIBE
“Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08”
Energy class35 °C applicationA+++ classeNIBE
“The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++”
Energy class55 °C applicationA+++ classeNIBE
“The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++”
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application195 %HP Keymark 012-C700115
“η s 195 % 150 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application163 %HP Keymark 012-C700115
“η s 163 % 131 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application150 %HP Keymark 012-C700115
“η s 195 % 150 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application131 %HP Keymark 012-C700115
“η s 163 % 131 %”
Heating capacityA-7/W35, max load8.34 kWNIBE
“Maximum capacity, heating, at A-7W35 kW 5.52 8.34 11.42 13.64”
Heating capacityA-7/W35, partial load7.23 kWNIBE
“Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64”
Heating capacityA2/W35, partial load3.67 kWNIBE
“Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63”
Heating capacityA7/W35, partial load3.67 kWNIBE
“7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55”
Heating capacityA7/W45, partial load3.35 kWNIBE
“7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12”
Operating range, cooling (outdoor air)—43 °CNIBE
“Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45”
Operating range, cooling (outdoor air)—15 °CNIBE
“Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45”
Operating range, heating (outdoor air)—38 °CNIBE
“Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40”
Operating range, heating (outdoor air)—-25 °CNIBE
“Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40”
Power input (heating)A-7/W35, partial load2.73 kWNIBE
“Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64”
Power input (heating)A2/W35, partial load0.85 kWNIBE
“Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63”
Power input (heating)A7/W35, partial load0.7 kWNIBE
“7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55”
Power input (heating)A7/W45, partial load0.85 kWNIBE
“7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12”
Rated heat output (Prated)average climate, 35 °C application6.8 kWHP Keymark 012-C700115
“Prated 6.80 kW 7.60 kW”
Rated heat output (Prated)average climate, 35 °C application6.8 kWNIBE
“Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00”
Rated heat output (Prated)colder climate, 35 °C application8.4 kWHP Keymark 012-C700115
“Prated 8.40 kW 8.40 kW”
Rated heat output (Prated)colder climate, 35 °C application8.4 kWNIBE
“Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00”
Rated heat output (Prated)warmer climate, 35 °C application7 kWNIBE
“Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00”
Rated heat output (Prated)average climate, 55 °C application7.6 kWHP Keymark 012-C700115
“Prated 6.80 kW 7.60 kW”
Rated heat output (Prated)average climate, 55 °C application7.6 kWNIBE
“Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00”
Rated heat output (Prated)colder climate, 55 °C application8.4 kWHP Keymark 012-C700115
“Prated 8.40 kW 8.40 kW”
Rated heat output (Prated)colder climate, 55 °C application8.4 kWNIBE
“Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00”
Rated heat output (Prated)warmer climate, 55 °C application7.45 kWNIBE
“Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00”
Refrigerant charge—0.8 kgHP Keymark 012-C700115
“Mass of Refrigerant 0,800 kg”
Refrigerant charge—0.8 kgNIBE
“Filling amount kg 0.8 0.8 1.15 1.15”
SCOPaverage climate, 35 °C application4.96 HP Keymark 012-C700115
“SCOP 4.96 3.83”
SCOPaverage climate, 35 °C application5 NIBE
“SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08”
SCOPcolder climate, 35 °C application4.15 HP Keymark 012-C700115
“SCOP 4.15 3.35”
SCOPcolder climate, 35 °C application4.2 NIBE
“SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69”
SCOPwarmer climate, 35 °C application6.3 NIBE
“SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78”
SCOPaverage climate, 55 °C application3.83 HP Keymark 012-C700115
“SCOP 4.96 3.83”
SCOPaverage climate, 55 °C application3.8 NIBE
“SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08”
SCOPcolder climate, 55 °C application3.35 HP Keymark 012-C700115
“SCOP 4.15 3.35”
SCOPcolder climate, 55 °C application3.4 NIBE
“SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69”
SCOPwarmer climate, 55 °C application4.6 NIBE
“SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 012-C700115
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 012-C700115
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 012-C700115
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 012-C700115
“Tbiv -15 °C -15 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 012-C700115
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 012-C700115
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 012-C700115
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 012-C700115
“TOL -22 °C -22 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.